TPO wet-laid waterproofing membrane
key word: Polymer waterproofing membrane system
Product Details
TPOWet-laid waterproofing membrane
★ Product Introduction
TPO wet-laid waterproofing membrane is an environment-friendly self-adhesive waterproofing membrane formed by thermoplastic elastomer TPO waterproofing membrane as the main material, coated with a layer of modified pressure-sensitive adhesive and isolation membrane. It is a waterproof material specially developed for waterproof pre-laid parts of buildings and is widely used in tunnels, basement floors, vertical walls, garages and underground projects.
★Product Specifications
Width: 2.0mThickness: 0.5-2.0mmLength: ≥20m
★Technical standard for polymer self-adhesive waterproofing membrane
"Pre-shop/Wet-laid Waterproofing Membrane GB/T 23457-2009
Table 1-1 Physical Property Index of Pre-paved Waterproofing Membrane
|
Serial Number |
Project |
Indicators |
||
|
P |
PY |
|||
|
1 |
Soluble content/(g/m²) ≥ |
— |
2 900 |
|
|
2 |
Tensile properties |
Tensile force/(N/50mm) ≥ |
500 |
800 |
|
Elongation at break of film,% ≥ |
400 |
— |
||
|
Elongation at maximum tension/% ≥ |
— |
40 |
||
|
3 |
Tear strength of nail shank/N≥ |
400 |
200 |
|
|
4 |
Impact performance |
Diameter (10±0.1)mm, no leakage |
||
|
5 |
static load |
20kg, no leakage |
||
|
6 |
Heat resistance |
No displacement, flowing and dripping at 70 ℃ for 2h |
||
|
7 |
Low temperature bending |
-25 ℃, no crack |
— |
|
|
8 |
Low temperature flexibility |
— |
-25 ℃, no crack |
|
Table 1-2 Physical Property Index of Wet-laid Waterproofing Membrane
|
Serial Number |
Project |
Indicators |
|||||
|
P |
PY |
||||||
|
Ⅰ |
Ⅱ |
Ⅰ |
Ⅱ |
||||
|
1 |
Soluble content/(g/m²) ≥ |
3.0 mm |
— |
2 100 |
|||
|
4.0 mm |
2 900 |
||||||
|
2 |
Tensile properties |
Tensile force/(N/50mm) ≥ |
150 |
200 |
400 |
600 |
|
|
Elongation at maximum tension/% ≥ |
30 |
150 |
30 |
40 |
|||
|
3 |
Tear strength/N≥ |
12 |
25 |
180 |
300 |
||
|
4 |
Heat resistance |
No displacement, flowing and dripping at 70 ℃ for 2h |
|||||
|
5 |
Low temperature flexibility/℃ |
-15 |
-25 |
-15 |
-25 |
||
|
No crack |
|||||||
|
6 |
impervious to water |
0.3 MPa, no water penetration for 120 min |
|||||
|
7 |
Peel strength between coil and coil/(N/mm) ≥ |
No treatment |
1.0 |
||||
|
Heat treatment |
1.0 |
||||||
Note:Products are divided into pre-paving according to the construction method (Y)Wet laying (W)
Products according to the main material is divided into polymer waterproofing membrane (P class), asphalt-based polyester tire waterproofing membrane (PY class)
Thickness of pre-laid waterproofing membrane :
Class P: pre-paved waterproof coiled material thickness: 0.7mm, 1.2mm, 1.5mm, the corresponding full thickness of the coiled material: 1.2mm, 1.7mm, 2.0mm
PY: 4.0mm
Thickness of wet-laid waterproofing membrane :
Class P (full thickness of coil): 1.2mm, 1.5mm, 2.0mm
PY: 3.0mm, 4.0mm
Table2 "Waterproof Coil with Self-adhesive Layer" Coil Self-adhesive Layer Physical Property Index GB/T 23260-2009
|
Serial Number |
Project |
Indicators |
|
|
1 |
Peel strength/(N/mm) |
Coil and coil |
≥ 1.0 |
|
Coil and aluminum plate |
≥ 1.5 |
||
|
2 |
Peel strength after immersion/(N/mm) |
≥ 1.5 |
|
|
3 |
Peel strength after thermal aging/(N/mm) |
≥ 1.5 |
|
|
4 |
Heat resistance of self-adhesive surface |
70 ℃, no flow for 2h |
|
|
5 |
Holding Tack/min |
≥ 15 |
|
Note: The waterproofing membrane with self-adhesive layer shall meet the requirements of the current product standards related to the main material, and the supplementary description of the performance affected by the self-adhesive layer is shown in the table.2
★ Product application range
Polymer self-adhesive waterproofing membrane can be applied to all kinds of concrete roof waterproofing in industry and construction industry, basement, subway tunnel, air raid shelter, grain depot, garbage disposal and other waterproof projects.
Hot Products
Product inquiry