HDPE pre-laid waterproof membrane with sand
key word: Polymer waterproofing membrane system
Product Details
HDPE pre-laid waterproof membrane with sand
★ Product Introduction
HDPE pre-paved waterproof coiled material with sand is also called high density polyethylene self-adhesive film) waterproof coiled material. It is an environment-friendly self-adhesive waterproof coiled material formed by high density polyethylene film as the main material, coated with a layer of modified pressure sensitive adhesive and anti-adhesive layer sand layer. It is a waterproof material specially developed for waterproof pre-paved parts of buildings and is widely used in tunnels, basement floors, vertical walls, garages and underground projects.
★Product Specifications
Width: 2.0mThickness: 0.5-2.0mmLength: ≥20m
Width:2.0m Thickness:0.5-2.0mm Length: 20m or more than 20m
★Technical standard for polymer self-adhesive waterproofing membrane
"Pre-shop/Wet-laid Waterproofing Membrane GB/T 23457-2009
Table 1-1 Physical Property Index of Pre-paved Waterproofing Membrane
|
Serial Number |
Project |
Indicators |
||
|
P |
PY |
|||
|
1 |
Soluble content/(g/m²) ≥ |
— |
2 900 |
|
|
2 |
Tensile properties |
Tensile force/(N/50mm) ≥ |
500 |
800 |
|
Elongation at break of film,% ≥ |
400 |
— |
||
|
Elongation at maximum tension/% ≥ |
— |
40 |
||
|
3 |
Tear strength of nail shank/N≥ |
400 |
200 |
|
|
4 |
Impact performance |
Diameter (10±0.1)mm, no leakage |
||
|
5 |
static load |
20kg, no leakage |
||
|
6 |
Heat resistance |
No displacement, flowing and dripping at 70 ℃ for 2h |
||
|
7 |
Low temperature bending |
-25 ℃, no crack |
— |
|
|
8 |
Low temperature flexibility |
— |
-25 ℃, no crack |
|
Table 1-2 Physical Property Index of Wet-laid Waterproofing Membrane
|
Serial Number |
Project |
Indicators |
|||||
|
P |
PY |
||||||
|
Ⅰ |
Ⅱ |
Ⅰ |
Ⅱ |
||||
|
1 |
Soluble content/(g/m²) ≥ |
3.0 mm |
— |
2 100 |
|||
|
4.0 mm |
2 900 |
||||||
|
2 |
Tensile properties |
Tensile force/(N/50mm) ≥ |
150 |
200 |
400 |
600 |
|
|
Elongation at maximum tension/% ≥ |
30 |
150 |
30 |
40 |
|||
|
3 |
Tear strength/N≥ |
12 |
25 |
180 |
300 |
||
|
4 |
Heat resistance |
No displacement, flowing and dripping at 70 ℃ for 2h |
|||||
|
5 |
Low temperature flexibility/℃ |
-15 |
-25 |
-15 |
-25 |
||
|
No crack |
|||||||
|
6 |
impervious to water |
0.3 MPa, no water penetration for 120 min |
|||||
|
7 |
Peel strength between coil and coil/(N/mm) ≥ |
No treatment |
1.0 |
||||
|
Heat treatment |
1.0 |
||||||
Note:Products are divided into pre-paving according to the construction method (Y)Wet laying (W)
Products according to the main material is divided into polymer waterproofing membrane (P class), asphalt-based polyester tire waterproofing membrane (PY class)
Thickness of pre-laid waterproofing membrane :
Class P: pre-paved waterproof coiled material thickness: 0.7mm, 1.2mm, 1.5mm, the corresponding full thickness of the coiled material: 1.2mm, 1.7mm, 2.0mm
PY: 4.0mm
Thickness of wet-laid waterproofing membrane :
Class P (full thickness of coil): 1.2mm, 1.5mm, 2.0mm
PY: 3.0mm, 4.0mm
Table2 "Waterproof Coil with Self-adhesive Layer" Coil Self-adhesive Layer Physical Property Index GB/T 23260-2009
|
Serial Number |
Project |
Indicators |
|
|
1 |
Peel strength/(N/mm) |
Coil and coil |
≥ 1.0 |
|
Coil and aluminum plate |
≥ 1.5 |
||
|
2 |
Peel strength after immersion/(N/mm) |
≥ 1.5 |
|
|
3 |
Peel strength after thermal aging/(N/mm) |
≥ 1.5 |
|
|
4 |
Heat resistance of self-adhesive surface |
70 ℃, no flow for 2h |
|
|
5 |
Holding Tack/min |
≥ 15 |
|
Note: The waterproofing membrane with self-adhesive layer shall meet the requirements of the current product standards related to the main material, and the supplementary description of the performance affected by the self-adhesive layer is shown in the table.2